SETTING FOR MODEL PB - FB (SETUP)
Set 01 Inputs from external contacts
Setup:

0 = Inputs from external contacts Disabled
1 = Inputs from external contacts Enabled
Set 02 Pulse time
Pulse time from 0.05 to 5.00 sec.
Set 03 Interval time
Interval time between ev. from 1 to 999 sec.
Set 04 Number of cleaning solenoid valve selection
Set 05 Number of additional cycles after fan stop
Set 06 Manual TEST of every single ev. from keyboard
By keyboard, it is possible to activate manually and individually every single output for an operation test.
Press key C to select the desired output to be activated. Press key A to activate the output.
The output is holded active for all the time that key A is pressed. It allows to measure the output voltage by using a tester.
In case of anomalous operating, do this test with electrovalves disconnected.
Set 07 Set up input from external contact 2 (14-15)
Setup:

0=C6 for connection to external pressure switch
1=D6 for connection to remote START/STOP contact
Set 08 Output voltage setup for ev. (see HV). Necessary for right operating of B8a
By keyboard, it is possible to activate manually and individually every single output for an operation test.
Press key C to select the desired output to be activated. Press key A to activate the output.
The output is holded active for all the time that key A is pressed. It allows to measure the output voltage by using a tester.
In case of anomalous operating, do this test with electrovalves disconnected.