A1a |
Minimum and maximum dP alarms on the same relay (K2) |
|
A1aoc |
Minimum and maximum dP alarms on same open collector output |
|
A1b |
Minimum (K1) and maximum (K2) dP alarms on separate relays |
|
A1b1 |
Minimum (K2) and maximum (K1) dP alarms on separate relays |
|
A1c |
Minimum (K3) and maximum (K2) dP alarms on separate relays |
|
A1e |
Minimum (K2), maximum (K2) and pre-alarm maximum dP (K3) on separate relays |
|
A1g |
Minimum (K3), maximum (K2) and pre-alarm maximum dP (K1) on separate relays |
|
A2a |
Relay Voltage ON (K1) |
|
A2b |
Relay voltage ON (K3) |
|
A2c |
Relay voltage ON according to D6x (K1) |
|
A2E |
Relay Voltage ON (K2) |
|
A2f |
Relay Ready/Fault (K3) |
|
A3a |
Relay K1 Cycle ON / OFF contact. Closed with active cycle |
|
A3ak2 |
Relay K2 Cycle ON / OFF contact. Closed with active cycle |
|
A3b |
Relay K1 Cycle ON / OFF. Open contact with active cycle |
|
A3c |
Relay K2 Work ON / OFF. Closed contact on operation |
|
A3d |
Relay K2 Work ON / OFF. Open contact on operation |
|
A3e |
Relay K1 Cycle ON / OFF contact. Closed with active cycle. Custom 1 |
|
A3e2 |
Relay K1 Cycle ON / OFF contact. Closed with active cycle. Custom 2 |
|
A3f |
Relay K1 Cycle ON / OFF contact. Closed with active cycle. Custom 2 |
|
A4a |
Impulsive contact end cycle by relay K1 |
|
A4aP |
Impulsive contact end cycle by relay K2 |
|
A4b |
Outputs activation on progress contact (K3) |
|
A4c |
Output relay contact for screw conveyor (K3) |
|
A5a |
Output contact by relay K3 sequencer running mode |
|
A5b |
Output contact by relay K1 additional cycles active |
|
A5c |
Output contact by relay K3 inclusion/exclusion inpiuts from external contacts |
 |
AF6 |
AISI 316 steel cable connection on sensing rod |
|
AL1 |
Alarm relay contacts open |
|
AL1oc |
Open collector outputs without voltage en alarm |
|
AP0 |
Non self-regulating anticondensate heater 20W |
|
AP1 |
Anticondensate heater ultra small model 50÷500W |
|
AP1.1 |
Anticondensate heater model ACT4 |
|
AP2 |
Anticondensate heater small model 50÷500W |
|
AP2.2 |
Anticondensate heater model ACT6 |
|
AT |
Tropicalisation of the Printed Circuit |
|
B10 |
Manual activation of every single output from keyboard |
|
B10a |
Manual activation of every single output from keyboard |
|
B10b |
Manual activation of every single output from keyboard |
|
B10c |
Manual activation of every single output from keyboard |
|
B10dm |
Manual activation of every single output from keyboard |
|
B1a |
Selection of the Number of outputs |
 |
B1a1 |
Pulse time for each valve from 50 to 1000 ms. |
|
B1aP |
Autoselection of the number of the output |
|
B1b |
Selection Number of outputs |
|
B1c |
Select Number of outputs |
 |
B1d |
Selection of the Number of outputs up to 192 |
|
B1r |
Selection of the Number of outputs with Dip-Switch |
|
B2a1 |
Pulse time for each valve from 50 to 1000 ms. |
 |
B2a3 |
Pulse time for each valve from 0.3 to 5.0 s. |
 |
B2a4 |
Pulse time for each valve from 1 to 60 s. |
|
B2g |
Different pulse time for manual and automatic run mode |
|
B2x |
Activation time from 0.05 to 5.00 sec. |
 |
B2x1 |
Activation time from 001 to 999 sec. |
 |
B2x2 |
Activation time from 00.1 to 99.9 sec. |
 |
B2x3 |
Activation time from 0.01 to 5.00 sec. |
 |
B3a |
Interval time between two activation from 1 to 60 s. |
|
B3a3 |
Interval time between two activation from 1 to 120 s. |
|
B3c |
Interval time between ev. during post-cleaning |
|
B3d |
Pause time proportional to dP (8 steps) |
|
B3e |
Pause time proportional to a 4-20 mA external signal (8 steps) |
|
B3e2 |
Pause time proportional to a 4-20 mA external signal |
|
B3f2 |
dP threshold to activate cleaning cycles with different interval time |
|
B3g |
Different interval times for manual and automatic operation |
|
B3h |
Interval time selection by external contact |
|
B3x |
Interval time from 1 to 999 sec. |
 |
B3x0 |
Interval time from 0.01 to 9.99 sec. |
 |
B3x1 |
Interval time from 1 to 999 min. |
|
B3x10 |
Interval time from 1 to 999 sec. |
 |
B3x2 |
Interval time from 10 to 9990 sec. |
|
B4a |
Interval time between chamber closing and cleaning start from 1 to 999 sec. |
|
B4b |
Decantation interval time from 1 to 999 sec. |
|
B4c |
Interval time between chambers from 1 to 999 sec. |
|
B5a2 |
End-of-cycle interval time 15÷120 sec. |
|
B5b2 |
End-of-cycle interval time 0÷999 minutes |
|
B5b3 |
End-of-cycle interval time 0÷999 sec |
|
B5b4 |
End-of-cycle interval time 0÷999 hours |
|
B5b4a |
End-of-cycle interval time 0÷999 hours every n cycle |
|
B6 |
Pneumatic control of the output activation (K2) |
|
B6-TP30 |
Pneumatic control of the output activation (K2) with TP30 |
|
B7a |
Output activation sequence programmable |
|
B8a |
Short-circuit protection of every single output |
|
B8b |
Short-circuit protection of every single output |
|
B8boc |
Short-circuit protection of every single output |
|
B8c |
Short-circuit protection of every single output (K3) |
|
B8P |
Short-circuit protection of every single output for sequencer P |
|
B9b |
Electric control of output activation |
|
B9b1 |
Electric control of output activation (after 3 cycles) |
|
B9boc |
Electric control of output activation |
|
B9c |
Electric control of output activation (Relay K3) |
 |
BP1 |
DC16/SC16 Sequencer and front panel fixing backplate |
 |
BP2 |
DC96/SC96 Sequencer and front panel fixing backplate |
 |
BP3 |
BB16 Sequencer fixing backplate to fit model B |
 |
BP4 |
PB/BB16 sequencer fixing backplate for enclosure 1.5 with complete cover of enclosure |
 |
BP5 |
PB/BB sequencer fixing backplate for enclosure 1.6 with complete cover of enclosure |
 |
BP7 |
DTC, DTP, DPC, NE, RE fixing backplate for enclosure 7.1/7.10 |
|
BS200 |
TC probe fastening bush until 200 °C - AISI 304 |
|
BS200H |
TC probe fastening bush 200 mm. AISI304 |
|
BS40 |
TC standard probe fastening bush (120 °C) - AISI 304 |
|
BS400 |
TC probe fastening bush until 400 °C - AISI 304 |
|
BS400H |
TC probe fastening bush 400 mm. AISI304 |
|
C0 |
Input activation from external contacts |
|
C1 |
Digital differential pressure control (STOP at cycle end) |
|
C10 |
dP threshold plant On/Off |
|
C10a |
dP threshold plant On/Off |
|
C11a |
4÷20 mA output signal of dP readout |
|
C11a1 |
4÷20 mA output signal for fan speed regulation |
|
C12 |
4÷20 mA output signal of TC probe readout |
|
C13_1 |
dP full range 1 kPa |
|
C13_10 |
dP full range 10.00 kPa = 100.0 mbar = 1012 mmH2O. |
|
C13_10mbar |
dp reading full range 100.0 mbar |
|
C13_10mm |
dP full range 1000 mmH2O |
|
C13_1mm |
dP full range 100 mmH2O |
|
C13_2 |
dP full range 2 kPa |
|
C13_20in |
dP full range 20 water inches |
|
C13_25mm |
dP full range 2500 mmH2O |
|
C13_2mbar |
dp reading full range 20.0 mbar |
|
C13_2mm |
dP full range 200 mm water coloum |
|
C13_3 |
dP full range 3 kPa |
|
C13_30in |
Fondo scala dP 30 pollici d'acqua |
|
C13_3mm |
Fondo scala dP 300 mmH2O |
|
C13_5 |
dP full range 5 kPa |
|
C13_5mm |
dP full range 500 mmH2O |
|
C13_7 |
dP full range 7 kPa |
|
C15 |
Precoating |
|
C15BB |
Precoating |
|
C1c |
Digital differential pressure control (instantaneous STOP) |
|
C1cBB |
Digital differential pressure control (instantaneous STOP) |
|
C1d |
Differential pressure digital control |
|
C1e |
Inclusion / Exclusion dP control with input contact D6x open |
|
C1Tx1 |
Digital differential pressure control (STOP at cycle end) |
|
C2a |
Additional cleaning cycles after a preset time |
|
C2b |
Additional cleaning cycle after a preset time (1 cycle only) |
|
C2c |
Forced activation of 1 solenoid valve after a preset time |
|
C2d |
Additional cleaning cycle from external contact |
|
C3 |
Differential pressure readout from internal transducer (max 10 kPa) |
 |
C3s |
Pressure readout from internal transducer (max 10 kPa) |
|
C4 |
Cleaning cycle |
|
C4a |
Automatic operation mode |
|
C4b |
Manual operation mode |
|
C4c |
Cleaning cycle |
|
C4sp1 |
Operating mode selection between 2 custom modality |
|
C4sp2 |
Custom modality operating mode sp2 |
|
C5a |
dP readout from external transducer supplied by the instrument |
|
C5b |
dP readout from external transducer with external supply |
|
C6 |
ON/OFF cleaning cycle from external pressure switch |
|
C6a |
ON/OFF cleaning cycle from external pressure switch. STOP at the end of the cycle |
|
C6aSB |
ON/OFF cleaning cycle from external pressure switch. STOP at the end of the cycle |
|
C6b |
ON/OFF cleaning cycle from external pressure switch. Instantaneous STOP |
|
C6c |
ON/OFF istantaneous cleaning cycle from external pressure switch |
|
C6P |
ON/OFF cleaning cycle from external pressure switch |
|
C7a1 |
Minimum dP alarm. Contact open with alarm. Event memory |
|
C7a2 |
Minimum dP alarm. Contact close with alarm. Event memory |
|
C7b1 |
Maximum dP alarm. Contact open with alarm. Event memory |
|
C7b2 |
Maximum dP alarm. Contact close with alarm. Event memory |
|
C7c1 |
Minimum dP alarm. Automatic reset. |
|
C7c1oc |
Minimum dP alarm. No voltage in alarm. Automatic reset. |
|
C7c2 |
Minimum dP alarm. Contact close with alarm. Automatic reset |
|
C7c2HF |
Minimum dP alarm. Contact close with alarm. Automatic reset |
|
C7d1 |
Maximum dP alarm. Automatic reset. |
|
C7d1oc |
Maximum dP alarm. No voltage in alarm. Automatic reset. |
|
C7d2 |
Maximum dP alarm. Contact close with alarm. Automatic reset |
|
C7d2HF |
Maximum dP alarm. Contact close with alarm. Automatic reset |
|
C7d2sv |
Maximum dP alarm. Contact close with alarm. Automatic reset |
|
C7d2_FC |
Maximum dP alarm. Contact close with alarm. Automatic reset |
|
C7f1 |
Maximum dP pre-alarm. Contact open with alarm. Automatic reset |
|
C7f2 |
Maximum dP pre-alarm. Contact close with alarm. Automatic reset |
|
C7f2HF |
Maximum dP pre-alarm. Contact close with alarm. Automatic reset |
|
C7h |
Special management of dP alarms and relais contacts |
|
C7r |
Min. and Max. dP alarms delay |
|
C8 |
dP zero readout regulation |
|
C8aut1 |
Automatic adjustment dP zero reading |
|
C9a |
Manual / Automatic operation from external contact |
|
C9a1 |
Manual / Automatic operation from external contact (Special) |
|
C9b |
ON / OFF dP control from external contact |
|
C9c |
Manual / Automatic operation from external contact with external relay |
|
CA1 |
1-way current / current insulator |
|
CB1 |
Non isolated transmitter with fixed range: input 4÷20 mA, output 4÷20 mA |
|
CF |
Fan with additional filter |
|
CF-M1 |
Fan with additional filter 230VAC 50÷60Hz 14W |
 |
CL-AOUT |
Additional antinoise filters on each output |
|
CS |
TC probe connection cable |
 |
D01 |
Enable 4 - 20 mA signal |
 |
D02 |
Zero adjustment of 4 - 20 mA signal reading |
 |
D03 |
4 - 20 mA signal amplification adjustment |
 |
D04 |
Average reading of 4 - 20 mA signal |
 |
D05 |
Two digital inputs |
 |
D06 |
Two digital outputs |
|
D11 |
Emission control by TRIBO-CHECK probe. |
|
D11a |
Emission control by TRIBO-CHECK probe. Alarms on relay K3. |
|
D11a_2 |
Emission control by TRIBO-CHECK probe. Alarms on relay K3. Connection of 1 TC probe to 2 sequencers |
|
D11c |
Emission control by TRIBO-CHECK probe. |
|
D11d |
Emission control by TRIBO-CHECK probe. |
 |
D12 |
TC high emission alarm activation delay |
|
D12a1 |
High emission pre-alarm threshold. Contact open with alarm. Automatic reset. |
|
D12a3 |
High emission pre-alarm. Contact close with alarm. Automatic reset |
|
D12a4 |
High emission pre-alarm. Contact close with alarm. Event memory |
|
D12b1 |
High emission alarm threshold. Contact open with alarm. Automatic reset |
|
D12b2 |
High emission alarm. Contact open with alarm. Event memory |
|
D12b3 |
High emission alarm. Contact close with alarm. Automatic reset. |
|
D12b4 |
High emission alarm. Contact close with alarm. Event memory |
|
D12c |
High emission alarm. |
|
D13a |
Include / Exclude TC probe control by external conatct 1 (clamps 12-13) |
|
D14a |
Operation hours-counter |
|
D14aBB |
Operation hours-counter |
|
D14c |
Operation hours-counter |
|
D14d |
Operation cycles-counter (x1) |
|
D16 |
RS485 serial line connection |
|
D16c1 |
RS485 serial line connection |
|
D17 |
TC probe readout zero regulation (-9÷+9 points) |
|
D18 |
Emission readout setup in mg/m3 |
|
D18dm |
Emission readout setup in mg/m3 |
|
D19 |
Mean TC probe readout time |
|
D1a |
Additional cycles after fan stop |
|
D1a3 |
Additional cycles from voltfree contact. ALWAYS enabled. |
|
D1a3SB |
Additional cycles from voltfree contact. ALWAYS enabled. |
|
D1ab1 |
Additional cycles after fan stop with fan mode selection. |
|
D1aNC |
Additional cycles after fan stop (Contact open = ventilator On) |
|
D1aP |
Additional cycles after fan stop |
|
D1b1 |
Post-cleaning cycles from dP readout. Activation at STOP. |
|
D1b1BC |
Additional post-cleaning cycles from dP readout. Activation at STOP. |
|
D1b1dm |
Additional post-cleaning cycles from dP readout. Activation at STOP. |
|
D1b2 |
Additional post-cleaning cycles from dP readout. Activation on START. |
|
D1b3 |
Additional post-cleaning cycles from dP readout. ALWAYS enabled. |
|
D1b3BA |
Additional cycles after fan stop with fan mode selection. ALWAYS enabled. |
|
D1c1 |
Additional post-cleaning cycles from external contact and dP. Activation at STOP |
|
D1r |
Delay on the activation of the additional post-cleaning cycles |
|
D20 |
TC probe signal readout in mA |
|
D21 |
Sensitivity for broken bag check |
|
D30 |
Relative humidity reading with special management type 1 |
 |
D4-EV1 |
1 pulse solenoid valves per chamber |
 |
D4-EV10 |
10 pulse solenoid valves per chamber |
 |
D4-EV11 |
11 pulse solenoid valves per chamber |
 |
D4-EV12 |
12 pulse solenoid valves per chamber |
 |
D4-EV13 |
13 pulse solenoid valves per chamber |
 |
D4-EV14 |
14 pulse solenoid valves per chamber |
 |
D4-EV15 |
15 pulse solenoid valves per chamber |
 |
D4-EV16 |
16 pulse solenoid valves per chamber |
 |
D4-EV18 |
18 pulse solenoid valves per chamber |
 |
D4-EV19 |
19 pulse solenoid valves per chamber |
 |
D4-EV2 |
2 pulse solenoid valves per chamber |
 |
D4-EV20 |
20 pulse solenoid valves per chamber |
 |
D4-EV24 |
24 pulse solenoid valves per chamber |
 |
D4-EV26 |
26 pulse solenoid valves per chamber |
 |
D4-EV3 |
3 pulse solenoid valves per chamber |
 |
D4-EV48 |
48 pulse solenoid valves per chamber |
 |
D4-EV5 |
5 pulse solenoid valves per chamber |
 |
D4-EV50 |
50 pulse solenoid valves per chamber |
 |
D4-EV6 |
6 pulse solenoid valves per chamber |
 |
D4-EV7 |
7 pulse solenoid valves per chamber |
 |
D4-EV8 |
8 pulse solenoid valves per chamber |
 |
D4-EV9 |
9 pulse solenoid valves per chamber |
|
D4-EVB |
Chamber system with bistable piston OPEN/CLOSE (2 ev. per chamber) |
|
D4-EVBM |
Chamber system with bistable piston OPEN/CLOSED (2 ev. per chamber) and magnetic latching relays |
|
D4-EVBOFF |
Chamber system with bistable piston OFF-LINE only |
|
D4-EVBON |
Chamber system with bistable piston ON-LINE only |
|
D4-EVM |
Chamber system with monostable piston with spring return |
|
D4-EVMOFF |
Chamber system with monostable piston with spring return OFF-LINE only |
|
D4-EVMON |
Chamber system with monostable piston with spring return ON-LINE only |
|
D4-EVMU |
Chamber system with monostable piston with spring return (Vout 24VDC) |
|
D4-FP1 |
FP1 system with chambers management |
 |
D4-NC1 |
1 Chambers |
 |
D4-NC10 |
10 Chambers |
 |
D4-NC11 |
11 Chambers |
 |
D4-NC12 |
12 Chambers |
 |
D4-NC14 |
14 Chambers |
 |
D4-NC16 |
16 Chambers |
 |
D4-NC2 |
2 Chambers |
 |
D4-NC3 |
3 Chambers |
 |
D4-NC4 |
4 Chambers |
 |
D4-NC5 |
5 Chambers |
 |
D4-NC6 |
6 Chambers |
 |
D4-NC7 |
7 Chambers |
 |
D4-NC8 |
8 Chambers |
 |
D4-NC9 |
9 Chambers |
|
D4-PC20 |
Additional board to activate isolating valves and additional output |
|
D4-SECH |
Output activation sequence for chambers |
|
D4-SECH2 |
Output activation sequence for opposite chambers |
|
D4c |
Chamber system with external management of pistons |
|
D4d |
Chamber system without management of pistons |
|
D4e |
Chamber system excluding chambers from external signals |
|
D4f |
Inputs management for air tank exclusion |
|
D4f2 |
Inputs management for air tank exclusion |
|
D5a |
Consent from external compressed air pressure switch |
|
D5aDB |
Consent from external compressed air pressure switch |
|
D5aI3 |
Consent from external compressed air pressure switch on input 3 |
|
D5aK1 |
Consent from external compressed air pressure switch |
|
D5aK3 |
Consent from external compressed air pressure switch |
|
D5b |
Consent from external compressed air pressure switch with external relay |
|
D6 |
ON/OFF Cleaning cycle from external contact. |
|
D6a |
ON/OFF cleaning cycle from external contact |
|
D6aDB |
ON/OFF cleaning cycle from external contact |
|
D6aI3 |
ON/OFF cleaning cycle from external contact (input 3) |
|
D6b |
ON/OFF Cleaning cycle from external contact with external relay |
|
D6c |
ON/OFF Cleaning cycle from external contact. Restart from stop point. |
|
D6c_ch |
ON/OFF Cleaning cycle from external contact. Restart from stop point. |
|
D6e |
ON/OFF Cleaning cycle from external contact. OFF at cycle end. |
|
D6P |
ON/OFF Cleaning cycle from external contact. |
|
D6P2 |
ON/OFF Cleaning cycle from external contact. |
|
D6s |
ON/OFF depression regulation from external contact |
 |
DECS0 |
HIGH DUST ALARM GENERATION |
 |
DECS1 |
VERY HIGH DUST ALARM GENERATION |
 |
DECS2 |
DATE AND TIME ADJUSTMENT |
 |
DECS3 |
DATA REGISTRATION IN CSV FILE (Excel) |
 |
DECS4 |
REMOTE WEBSERVER INTERFACE |
|
DINE4-16 |
Digital inputs for exclusion of chambers |
|
DINE4-16ms |
auto_awesome Forse cercavi: Ingressi da contatti esterni per gestione sequenziatori remoti 62 / 5000 Risultati della traduzione Inputs from external contacts for remote sequencer management |
|
DINE4-8 |
Digital inputs for exclusion of chambers |
|
DINE4-8b |
Digital inputs for exclusion of all chambers |
|
DINE4-8ON |
Digital inputs for exclusion of chambers |
|
DINE5 |
ON-LINE / OFF-LINE operation selection from external contact |
 |
DL1 |
|
 |
DL4-20 |
Datalogger for 4÷20 mA signals |
 |
DOORSW |
Door microswitch 10/500V IP45 |
 |
DP2 |
Pneumatic connections +P1 and -P2 available |
 |
DP3 |
Air connections 3x5 RILSAN pipe |
|
DPa |
Air connections 6x4 RILSAN pipe |
 |
DPb |
Air connections INOX AISI316L for 6 mm pipe |
 |
DPc |
Air connections for RILSAN pipe 8x6 |
 |
DPe |
Bulkhead for COPPER / INOX pipe 8 mm |
 |
DPe10 |
INOX Bulkhead for INOX pipe 10 mm |
 |
DPe12 |
AISI 316L stainless steel connection for 12 mm stainless steel pipe |
 |
DPg |
RILSAN air connections 5x2 - 6x4 |
|
DS1 |
LED display 57 mm. |
|
E1 |
3A 240V Power switch on device board |
|
E1-ExdIIC |
2 poles 20A external power switch Exd |
|
E1b |
3A 240V Power switch |
|
E1c |
16A 400V three-pole Power Switch |
|
E1ds |
Power switch with external door lock (type SI) |
|
E1Ex |
2 poles 20A external power switch Exd |
|
E1ExIIC |
Cam rotary switch with frontal drive Exd II2GD IIC |
|
E1_3 |
3A 240V Power switch on device board (3 contacts). |
|
E2 |
START / STOP selector |
|
E2-ExdIIC |
START / STOP selector Ex d |
|
E2Ex |
START / STOP selector Ex d |
|
E3 |
MANUAL - AUTOMATIC selector |
|
E3a |
MANUAL - 0 - AUTOMATIC selector |
|
E3ak |
MANUAL - 0 - AUTOMATIC selector with key |
|
E3b |
LOCAL - REMOTE selector |
|
E3b-ExdIIC |
LOCAL - REMOTE selector Ex d |
|
E3bEx |
LOCAL - REMOTE selector Ex d |
|
E3d |
LOCAL - 0 - REMOTE selector. |
|
E3dk |
LOCAL - 0 - REMOTE key selector |
|
E3Ex |
MANUAL - AUTOMATIC selector for Exd enclosure |
|
E4 |
Selectors for chamber exclusion |
|
E4ksv |
Selector for chamber exclusion forn remote unit |
|
E4k_4 |
3 positions key selectors for chamber exclusion (4 contacts) |
|
E4OFF |
Selectors for chamber exclusion (Off-Line) |
|
E4ON |
Selectors for chamber exclusion (On-Line) |
|
E4_2 |
Selectors for chamber exclusion 2 contacts |
|
E4_2ON |
Selectors for chamber exclusion 2 contacts (On-Line) |
|
E4_3 |
Selectors for chamber exclusion 3 contacts |
|
E4_3.1 |
Selectors for chamber exclusion 3 contacts. Type 1 custom version |
|
E4_4.1b |
Selectors for chamber exclusion 4 contacts. Type 1b custom version |
|
E5 |
ON-LINE / OFF-LINE selector |
|
E5_2 |
ON-LINE / OFF-LINE selector 2 contacts |
|
E6k |
Key selectors for electric cutoff of piston lines |
|
E6k2 |
Key selectors for electric cutoff common line for chamber ev. |
|
E6k_3 |
LOC 0 REM Key selectors for electric cutoff of piston lines |
|
E7 |
Selectors for air tank exclusion |
|
E7b |
Selectors for air tank exclusion (exclusion of more tanks at the same time) |
|
EPOX |
Main board encapsulation |
|
Ex20PTC |
Exd M20 Cable glands |
 |
Exd-SVM |
Fornt door green lamp for Exd enclosure 230VAC |
 |
ExdPB-B1 |
Blue push button for Exd enclosure with 1 contact NO |
|
ExdPC1-2ANPT |
Cable glands Exd-Exe NPT 1/2'' for armoured cable |
|
ExdPC1-2NX |
Cable glands Exd NPT 1/2'' INOX AISI316L |
|
ExdPC1-2NXK |
Cable glands Exd NPT 1/2'' INOX AISI316L for cables without armour. |
|
ExdPC16X |
Cable glands Exd / Exe M16 INOX AISI316L |
|
ExdPC20 |
Exd M20 Cable glands |
|
ExdPC20A |
Cable glands Exd M20 for armoured cable |
|
ExdPC20AX |
Cable glands Exd M20 for armoured cable AISI316L |
|
ExdPC20LT |
Exd M20 Cable glands. Low temperature |
|
ExdPC20X |
Cable glands Exd / Exe M20 INOX AISI316L |
|
ExdPC20X_0 |
Cable glands Exd / Exe M20 INOX AISI316L for reduced cable diameter lock |
|
ExdPC20_0 |
Cable glands Exd M20 for reduced cable diameter lock |
|
ExdPC20_1 |
Cable glands Exd M20 |
|
ExdPC25 |
Exd M25 Cable glands |
|
ExdPC25A |
Cable glands Exd M25 for armoured cable |
|
ExdPC25AX |
Cable glands Exd M25 for armoured cable AISI316L |
|
ExdPC25LT |
Exd M25 Cable glands. Low temperature |
|
ExdPC3-4 |
Cable glands Exd 3/4'' GAS |
|
ExdPC3-4NX |
Cable glands Exd NPT 3/4'' INOX AISI316L |
|
ExdPC32 |
Exd M32 Cable glands |
|
ExdPC32A |
Cable glands Exd M32 for armoured cable |
|
ExdPC32AX |
Cable glands Exd M32 for armoured cable AISI316L |
|
ExPC20T |
Exd M20 Cable gland |
|
ExPC32T |
Exd M32 Cable gland |
|
FCP1 |
Piston limit switch management type 1 |
|
FCP3 |
Piston limit switch management type 3 |
|
FCP4 |
Piston limit switch management type 4 |
 |
FG1 |
Filtering grid 115x115 IP54 |
|
FH0 |
5x20 fuse carrier 1 pole on DIN guide |
|
FH0k |
5x20 fuse carrier 1 pole on Omega guide |
|
FH0x |
5x20 fuse carrier 1 pole on DIN guide |
|
FH2 |
10x38 fuse carrier 2 poles on DIN guide |
|
FL-M13 |
Internal cabinet fluorescent lamp |
|
FP-70 |
Front panel with flat cable for standard enclosure 7.0 (max. 30 cm.). |
|
FP-71 |
Pannello frontale per apparecchiatura con tastiera e display con cavo piatto di collegamento alla scheda principale per contenitore standard 7.1(max. 30 cm.) |
|
FP-72 |
Front panel with flat cable for standard enclosure 7.2 (max. 30 cm.). |
|
FP-ST |
Pannello frontale per apparecchiatura con tastiera e display inserito in un tronchetto di alluminio 92x92x20mm. per fissaggio a fronte quadro con cavo piatto di collegamento alla scheda principale lun |
|
FP100 |
Front panel with 100 cm. flat cable |
|
FP150 |
Front panel with 150 cm. flat cable |
|
FP200 |
Front panel with 200 cm. flat cable |
|
FP300 |
Front panel with 300 cm. flat cable |
|
FP50 |
Front panel with 50 cm. flat cable |
|
FT-70 |
Front panel replacement with flat cable for standard enclosure 7.0 (max. 30 cm.). |
|
FT-71 |
Front panel replacement with flat cable for standard enclosure 7.1 (max. 30 cm.). |
|
FT100 |
Spare keyboard with 100 cm. flat cable |
|
FT200 |
Spare keyboard with 200 cm. flat cable |
|
G1 |
Maximum load power 25W per output |
 |
G2 |
Control of 2 solenoid valves on each output (2 x 25 W Max) |
 |
G4 |
Control of 4 solenoid valves on each output (4 x 25 W Max) |
 |
G8 |
Control of 8 solenoid valves on each output (8 x 25 W Max) |
|
GSM1 |
GSM network connection for SMS sending in case of alarm |
|
GSM2 |
GSM network connection for datas sending to database ESAWEB |
|
HS |
High-sensitivity TC probe |
|
HV |
Input / Output voltage selection. |
|
HVA |
Input voltage selection |
|
HVB |
Input and output voltage selection |
|
HVC |
Input voltage selection |
|
HVP |
Input / Output voltage selection. |
|
HW-PC16 |
Additional board to activate up to 16 output |
 |
IA1 |
1A bipolar automatic switch |
 |
IA10 |
10A bipolar automatic switch |
 |
IA10K |
10A bipolar automatic switch with door lock |
|
IA10sv |
10A Residual current circuit breaker with 30mA sensitivity |
 |
IA16 |
16A bipolar automatic switch |
 |
IA2 |
2A bipolar automatic switch |
 |
IA4 |
4A bipolar automatic switch |
 |
IA6 |
6A bipolar automatic switch |
|
Kb1 |
Keypad lock |
|
Kb3 |
Protected Menu Access |
 |
Kb50 |
50 cm button cable carryover. |
 |
Kb60 |
60 cm button cable carryover. |
 |
Kb70 |
70 cm button cable carryover. |
|
L01 |
DIN terminal rail with 1-way single terminals for uses. |
|
L01k |
Omega terminal rail with 1-way single terminals for I/O signal. |
|
L01m |
Omega terminal rail with 1-way single sping terminals for I/O signal. |
|
L01mph |
Omega terminal rail with 1-way single sping terminals for I/O signal. |
|
L01s |
4mm2 terminal rail with test breaker for I/O signal |
|
L01x |
DIN terminal rail with 1-way single terminals for signals (ATEX). |
|
L02 |
DIN terminal rail with 1-way double terminals for uses |
|
L02k |
Omega terminal rail with 1-way double terminals for uses |
|
L05 |
DIN terminal rail with 2-way multiple terminals for uses |
|
L10E1 |
Single terminal board of the board for power switch |
|
L11E1 |
Single coupling terminal board of the board for power switch |
|
L11TR |
Single coupling terminal board of the board for external transformer |
|
L20 |
Double clamps on the board |
|
L31 |
Terminal DIN rail with 1-way single terminals for electrovalves. |
|
L31k |
Terminal Omega rail with 1-way single terminals for electrovalves. |
|
L31m |
Omega terminal rail with 1-way single sping terminals for electrovalves |
|
L31x |
Terminal DIN rail with 1-way single terminals for electrovalves (ATEX). |
|
L32 |
DIN terminal rail with 1-way single terminals (2 wires) for electrovalves. |
|
L32k |
Terminal Omega rail with 1-way single terminals for electrovalves (2 wires). |
|
L41 |
DIN terminal rail with 1-way double terminals (2 wires) for electrovalves. |
|
L41k |
Omega terminal rail with 1-way double terminals (2 wires) for electrovalves. |
|
L42 |
DIN terminal rail with 1-way double terminals (1 common) for electrovalves. |
|
L42k |
DIN terminal rail with 1-way double terminals (1 common) for electrovalves. |
|
L51 |
DIN terminal rail with 1-way double terminals for electrovalves (2 loads, 1 common). |
|
L52 |
DIN terminal rail with 2-way multiple terminals for electrovalves (2 loads, 1 common). |
|
L62 |
DIN terminal rail with 2-way multiple terminals for electrovalevs (2 loads, 4 wires). |
|
L63 |
DIN terminal rail with 1-way double terminals for electrovalves (2 loads, 4 wires). |
|
L63k |
DIN terminal rail with 1-way double terminals for electrovalves (2 loads, 4 wires). |
|
L73 |
DIN rail terminal block with double terminals with diodes (2 wires) |
|
L81 |
DIN terminal rail with 1-way double terminals for electrolves (4 loads, 8 wires). |
|
L81k |
Omega terminal rail with 1-way double terminals for electrovalves (4 loads, 8 wires). |
|
L82 |
DIN terminal rail with 2-way multiple terminals for electrovalevs (4 carichi, 8 fili). |
 |
LA04 |
Board with additional terminal 4 Common (2.5 mm2 - 250V - 12A) |
 |
LA08 |
Board with additional terminal 8 Common (2.5 mm2 - 250V - 12A) |
 |
LA12 |
Board with additional terminal 12 Common (2.5 mm2 - 250V - 12A) |
 |
LA16 |
Board with additional terminal 16 Common (2.5 mm2 - 250V - 12A) |
 |
LA20 |
Board with additional terminal 20 Common (2.5 mm2 - 250V - 12A) |
 |
LA24 |
Board with additional terminal 24 Common (2.5 mm2 - 250V - 12A) |
 |
LA28 |
Board with additional terminal 28 Common (2.5 mm2 - 250V - 12A) |
 |
LA32 |
Board with additional terminal 32 Common (2.5 mm2 - 250V - 12A) |
 |
LB02Ex |
Additional terminal 4 common (2.5 mm2 - 250V - 12A) on sequencer card |
|
LC2 |
Transparent membrane for keyboard IP65 |
 |
LG1 |
12 module earth bar |
 |
LG2 |
24 modules earth bar |
|
LPE1 |
Earth terminal on DIN guide with 1-way single terminal. |
|
LPE1k |
Earth terminal on Omega guide with 1-way single terminal. |
|
LPE1m |
Earth terminal on Omega guide with 1-way single spring terminal. |
|
LPE1mph |
Earth terminal on Omega guide with 1-way single spring terminal. |
|
LPE1x |
Earth terminal on DIN guide with 1-way single terminal (ATEX). |
 |
LS |
TC probe with reduced sensitivity |
 |
LT |
Minimum probe operating temperature -40°C |
|
MB-CONV |
RS485-MODBUS RTU Converter |
|
MB-ETH |
RS485-MODBUS TCP/IP Converter |
|
MFR-B |
Xenon red Beacon 24VDC/24VAC |
|
MFR-M |
Xenon red Beacon 115/230VAC |
|
PC1-2EX |
Cable glands Exd GAS UNI 6125 1/2'' |
|
PC1-2EXdA |
Cable glands Exd GAS UNI 6125 1/2'' for armoured cable |
|
PC16 |
M16 Cable gland |
 |
PC16AT |
M16 ATEX Cable gland Exe |
|
PC16ME |
M16 Brass/nickel cable glands |
|
PC16MEAT |
Brass/nickel cable glands M16 ATEX Exe |
|
PC20 |
M20 Cable glands |
|
PC20AT |
M20 ATEX Cable gland Exe |
|
PC20INOX |
Stailess steel AISI303 M20 cable glands |
|
PC20ME |
Brass/nickel cable glands M20 |
|
PC20MEAT |
Brass/nickel cable glands M20 ATEX Exe |
|
PC20MELT |
Brass/nickel cable glands M20 (low temperature) |
|
PC20TC |
Brass/nickel cable glands M20 |
|
PC25 |
M25 Cable glands |
|
PC25AT |
M25 ATEX Cable gland Exe |
|
PC25INOX |
Stailess steel AISI303 cable glands M25 |
|
PC25ME |
Brass/nickel cable glands M25 |
|
PC25MEAT |
Brass/nickel cable glands M25 ATEX Exe |
|
PC25MELT |
Brass/nickel cable glands M25 (low temperature) |
|
PC32 |
M32 Cable glands |
|
PC32AT |
M32 ATEX Exe Cable gland |
|
PC32ME |
Brass/nickel cable glands M32 |
|
PC40 |
M40 Cable glands |
|
PC50 |
M50 Cable glands |
|
PF |
Filtered connections |
 |
PFB-ADP |
ProfiBus network adapter |
 |
PFB-AN |
Analog input 4 channels 4÷20 mA |
 |
PFB-CNT |
D-SUB 9 poles Profibus connector |
|
PFB-CONV |
RS485-PROFIBUS Converter |
|
PFN-CONV |
RS485-PROFINET Converter |
|
PL-A |
Electropilot 24VDC ASCO NUMATICS |
|
PL-A1 |
Electropilot 24VDC ASCO NUMATICS 257 |
|
PL-T |
Electropilot 24VDC |
|
PL-TG |
Electropilot 48VDC |
|
PL-THP |
High performance Pilot valves 24VDC |
|
PL-TM |
Electropilot 230VAC |
 |
PM1-2 |
Threaded hole 1/2'' GAS |
 |
PM1-2b |
1/2'' hole |
 |
PM1-2NPT |
Threaded hole 1/2'' NPT |
 |
PM13 |
Hole diameter 13.5 mm |
 |
PM16b |
Hole diameter 16 mm |
 |
PM1b |
1'' hole |
 |
PM20 |
Threaded hole M20 |
 |
PM20b |
Hole diameter 20 mm |
 |
PM22b |
Hole diameter 22 mm |
 |
PM25 |
Threaded hole M25 |
 |
PM25b |
Hole diameter 25 mm |
 |
PM3-4 |
Threaded hole 3/4'' GAS |
 |
PM3-4b |
3/4'' hole |
 |
PM3-4NPT |
Threaded hole 3/4'' NPT |
 |
PM32 |
Threaded hole M32 |
 |
PR |
6x4 Rilsan pipe |
 |
PRDC |
5x2 Silicon pipe |
|
RA230 |
Optical / Acoustic signalling lamp 230VAC |
|
RB2 |
Additional relay on DIN guide 2 contacts, 24VAC coil |
|
RB3 |
Additional relay on DIN guide 3 contacts, 24VAC coil |
|
RG2 |
Additional relay on DIN guide 2 contacts, 48VDC coil |
|
RL2 |
Additional relay on DIN guide 2 contacts, 115VAC coil |
|
RL3 |
Additional relay on DIN guide 3 contacts, 115VAC coil |
|
RM2 |
Additional relay on DIN guide 2 contacts, 230VAC coil |
|
RM3 |
Additional relay on DIN guide 3 contacts, 230VAC coil |
 |
RS-CONV |
USB-RS485 converter |
|
RU2 |
Additional relay on DIN guide 2 contacts, 24VDC coil |
|
RU2RIT |
Additional relay with retention on DIN guide 2 contacts, 24VDC coil |
|
RU3 |
Additional relay on DIN rail 3 contacts, 24VDC coil |
|
RU4 |
Additional relay on DIN guide 4 contacts, 24VDC coil |
|
RUB1 |
Settings 4 different activation times by dip-switch |
|
RUB2 |
Settings 4 different pause times by dip-switch |
|
RUB3 |
3 post-cleaning cycles after fan stop |
|
RUB4 |
Double terminal board for connection of solenoid valves |
|
SL |
Multi language display |
|
SRB |
Red signalling light 24V |
|
SRL |
Red signalling light 115V |
|
SRM |
Red signalling light 230V |
|
SVB |
Green signalling light 24V |
|
SVL |
Green signalling light 115V |
|
SVM |
Green signalling light 230V |
|
SWC-204 |
Fan managing in manual run mode too |
|
SWC-205 |
Impulsive enable activation of 1 valves |
|
SWC-206 |
Max. dP alarm on relay K3 |
|
SWC-206b |
Max. dP alarm on relay K1 |
|
SWC-209 |
Input to force 1 cycle with intermediate times |
|
SWC-209b |
Input to force 1 cycle with intermediate times |
|
SWC-210 |
Input to force cycles with intermediate times 2 |
|
SWC-303 |
Cleaning cycle sequencer direction selection |
|
SWC-305 |
Dust emission control only between cells with cell exclusion |
|
SWC-403 |
Pulse time for chambers isolating valves |
|
SWC-405 |
Dumping dust valves activation |
|
SWC-406 |
Custom outputs activation sequence |
|
SWC-408 |
Cleaning cycle management by zone related to dP reading (type 1) |
|
SWC-409 |
Interval time regulation by dP reading |
|
SWC-410 |
Postcleaning cycle on excluded chamber |
|
SWC-411 |
Selector to set cleaning cycle in series or in parallel |
|
SWC-502 |
Forced cycle in On-line and manual mode |
|
SWC-503 |
Temperature control |
|
SWC-702 |
Bypass management by external contact |
|
SWC-703 |
Selection between 2 cleaning cycle sequence by keyboard: standard / by chambers |
|
T01 |
Temperature control via external sensor |
|
T03 |
Temperature probe signal reading in mA |
|
T04_10 |
Full scale temperature reading 100 ° C |
|
TA-1NX |
Plug INOX AISI316 and ATEX certified Exe for zone 1, 21 for 1'' NPT hole |
|
TA-1_2NX |
Plug INOX AISI316 and ATEX certified Exe for zone 1, 21 for 1/2'' NPT hole |
|
TA-3_4NX |
Plug INOX AISI316 and ATEX certified Exe for zone 1, 21 for 3/4'' NPT hole |
|
TA-M16Exe |
ATEX certified Exe for zone 1, 21 for M16 holes |
|
TA-M20 |
Hole diameter 20 mm with plug |
|
TA-M20XExe |
ATEX certified Exe for zone 1, 21 for M20 holes INOX plug |
|
TA-M25 |
Hole diameter 25 mm with plug |
|
TA-M25ExeX |
Plug INOX AISI316 and ATEX certified Exe for zone 1, 21 for M25 holes |
|
TA-M32Exe |
ATEX certified Exe for zone 1, 21 for M32 holes |
 |
TA22 |
Hole diameter 22 mm with plug |
|
TAM20Ex |
Hole diameter 20 mm with plug Exd-Exe |
|
TC42 |
Kit steel cable with ceramic isolator |
|
TEMP1 |
EXTENDED OPERATING TEMPERATURE RANGE -40°C÷50°C |
|
TEMP4 |
EXTENDED OPERATING TEMPERATURE RANGE -20°C÷50°C |
|
TEMP5 |
EXTENDED OPERATING TEMPERATURE RANGE -30°C÷50°C |
|
TEMP6 |
EXTENDED OPERATING TEMPERATURE RANGE -20°C÷55°C |
|
TEMP8 |
EXTENDED OPERATING TEMPERATURE RANGE -25°C÷50°C |
|
TR100RM-BZ |
External transformer 100 VA, 230-400V / 24-48V |
|
TR200L-L |
External transformer 200 VA, 115V / 115V |
|
TR220RM-ML |
External transformer 100 VA, 220 VA, 230-400V / 230-115V |
|
TSW |
On/Off temperature adjustable switch |
 |
TT320 |
Protective roof 300Lx200P |
 |
TT320X |
Protective roof 300Lx200P INOX AISI304L |
 |
USB-1 |
Connection via USB port |
|
VA24-0.6 |
Switching voltage stabilized supplier 24VDC 0.6A |
|
VA24-2.5 |
Switching voltage stabilized supplier 24VDC 3A |
|
VDD |
Exd drain valve |
 |
VER-B |
Double layer painting RAL7035 with anticorrosive pigments |
|
VS300 |
Voltage stabilizer 230VAC / 300VA |
|
VSD |
Exd Leak valve |