SEQUENCER WITHOUT DIFFERENTIAL PRESSURE CONTROL: LG
 
CODE    
 
SETTING OPERATING PARAMETERS OPTIONS ON REQUEST
 
  Select number of outputs A3a - Relay K1 Cycle ON / OFF contact. Closed with active cycle  
  B9b - Short-circuit protection of every single output for sequencer P  
  Select power supply voltage AT - Tropicalisation of the Printed Circuit  
  LC2 - Transparent membrane for keyboard IP65  
  Select voltage for solenoid valves
       
 

     
STANDARD FEATURES
 
Info Code Description
 
A2a Relay Voltage ON (K1)
B10 Manual activation of each single output from the keyboard
B1b Select Number of outputs
  B2x Activation time from 0.05 to 5.00 sec.
B3c Interval time between ev. during post-cleaninges
B3x Interval time from 1 to 999 sec.
B8b Short-circuit protection of every single output
C4c Cleaning cycle
C6a ON/OFF cleaning cycle from external pressure switch. STOP at the end of the cycle
D14a Operation hours-counter
D1a3 Additional cycles from voltfree contact. ALWAYS enabled.
D6a ON/OFF cleaning cycle from external contact
  G1 Maximum load power 25W per output
SL Multi language display
TECHNICAL FEATURES
 
  • LCD alphanumeric display 32 characters multilanguage
  • Italian, English, French, German, Spanish
  • Supply voltage: 115 VAC ÷ 230 VAC / 50 ÷ 60 Hz (Standard)
  • Supply voltage (On request): 24 VAC / 50
  • Voltage electrovalves: 24 VAC, 115 VAC, 230 VAC / 50 ÷ 60 Hz, 24 VDC
  • Operating temperature: - 10 ÷ + 50 °C (Standard)
  • Power consumption: 10 VA (Stand-by) - 30 VA Max
  • Sequencers with digital dP control 6 / 12 outputs for electrovalves